DS 9200C - INFLATE FAILURE RESEND RFU OVER NETWORK PORT

DS 9200C infinite LOOP BOOT

In the start up
After memory counting 128MB
Appears the message
INFLATE FAILURE RESEND RFU OVER NETWORK PORT
followed by
RFU RECEIVED CYCLING POWER

And after this the machine try another time to boot in an infinite loop

There are a keyboard method to clearing RFU errors. Please could anyone explain this method?

Thanks in advance
Reply
0
Intern
Posts: 39
Member Since: ‎05-19-2015
Message 2 of 2 (146 Views)

Re: DS 9200C - INFLATE FAILURE RESEND RFU OVER NETWORK PORT

Hello Ccsa,

 

Try a Cold Reset first. If not then replace formatter board.

 

To perform a cold reset

 

1. Turn off the digital sender.

2. Turn on the digital sender.

3. Immediately after turning on the device, press and hold down the #6 key (do not wait for the memory-count). When the three status LEDs are illuminated, release the #6 key.

4. Press the #3 key four times until the display shows COLD RESET.

5. Press the #6 key once to initiate the cold reset. The product will continue its boot-up sequence.