Create an account on the HP Community to personalize your profile and ask a question
05-22-2025
08:38 AM
- last edited on
05-22-2025
12:20 PM
by
Raj_05
I have a Latex 365 Model # V8L39A Serial Number is Edited. I have a curing module assembly that has gone bad in position #2. I ordered the part out of the manual and it looks to be the same except for the the plug that the thermistor connects to. The one in our machine has a three pin plug and the ones I receive have a smaller 2 pin plug. I removed the pins and used the pug off the one that failed, but I still got the error code. I moved the assembly to position #1 and the error code moves to #1 position. That tells me that my wiring and power sources are correct. Does anyone know what the incompatibility issue is and what the correct part is?