Hi! Any advice on how to check/trace signal path for MP feed Solenoid?

3 REPLIES 3
HP Recommended

According to the service manual, the MP feed solenoid is connected to connector # J209 on driver PCA.

 

j209.jpg.png




My profile on LinkedIn

HP Recommended

Thank you for an informative reply. I do have the service manual and sort of know where SL1 connects. However, I need to trace signal path to check if signal is present that actuate the said solenoid. On my driver PCA the connector J209 has no output when a signal is expected. 

HP Recommended

Driver PCA is very simple electronics, use a multimeter to isolate possible defect, starting from solenoid connector and heading to the connector to DC controller.  Tracing digital signal on the DC controller is way to complicated.




My profile on LinkedIn

† The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the <a href="https://www8.hp.com/us/en/terms-of-use.html" class="udrlinesmall">Terms of Use</a> and <a href="/t5/custom/page/page-id/hp.rulespage" class="udrlinesmall"> Rules of Participation</a>.